Udendørs LED-koldstart: Strømforsyninger og systemtjek
“It runs in winter” and “it restarts after a long winter outage” describe different requirements. For an unattended outdoor screen, put the lowest required restart temperature, expected outage duration and available site supply in the quotation request. Then select the power and enclosure configuration against that event.
Define what happens when power returns
A screen already operating generates heat. After a long outage, the cabinet, control box and power supply can approach the surrounding temperature. State whether the display must resume immediately or may warm up before playback. A storage rating answers neither question.
| Krav | Hvad skal optages |
|---|---|
| Koldstart | Starting temperature, duration without power and input conditions |
| Driftsforhold | Temperature and duty after successful startup |
| Genopretningsadfærd | Permitted delay, automatic playback and fault indication |
| Accept | Ordered components, measurement points and observed system result |
Select the power route for the ordered cabinet
Standard Square can use the optional Megmeet MCP300WS-4.5A-B. Its power-supply specification allows startup and operation at −40°C. Output depends on the input and thermal conditions; the unit’s nominal 4.5 V, 60 A rating is not available unconditionally across its entire input range.
Square Pro uses the Xingxiu dual-voltage power solution for −40°C startup. That is a power configuration, not a blanket cold-start rating for every complete display. Select Pro if its cabinet or power platform fits the project; a low-temperature requirement can also be evaluated on standard Square.
Plan the heated-control-box option
For a Pro project with an extreme ambient requirement of −50°C, a thermostatically controlled heater can be added inside the control box. Agree where temperature is sensed, what equipment is energised first and when the controller permits playback. The heater option is a design route; the time until the first stable image is a separate acceptance item.
Verify the screen as installed
Record the final bill of materials, temperature and soak period, supply conditions, controller recovery and first stable image. If the owner requires unattended recovery, repeat the agreed shutdown and restart sequence with the production configuration. Record the result for the assembled system separately from any component-level test report.
- Emne
- Udendørs LED-koldstart: Strømforsyninger og systemtjek
- Udvælgelse
- “It runs in winter” and “it restarts after a long winter outage” describe different requirements. For an unattended outdoor screen, put the lowest required restart temperature, expected outage duration and available site supply in the quotation request. Then select the power and enclosure configuration against that event.
- Konfiguration
- Square 960
Does a -40°C operating range prove cold startup?
Can standard Square use a cold-start power supply?
Does a power-supply test certify the complete screen?
Is a heater required for every cold-climate installation?
How long does a cold start take?
What should a restart test record?
Diskuter dine lysstyrkekrav
Fortæl os, hvad skærmen skal kunne. Vi kan foreslå en Square-konfiguration og bekræfte lysstyrke- og effektoplysningerne til dit tilbud.
Send en anmodning